5
to the multi hose adapter, preferably cutting off the other two stages at the groove at the
end of the 1” dia. step.
Alternatively, you may remove the multi adapter
altogether, and screw on a 1-1/4” BSP hose adapter
as shown in fig.2.
The pump is completely submersible, and should
be placed in a vertical position, on a solid flat surface.
If this is not available, sit the pump a solid surface, eg. house bricks, but ensure they are
not likely to shift.
IMPORTANT:
ALWAYS raise and lower the pump using a rope attached to the lifting handle, NEVER
by the power cable.
Automatic versions should be placed in a sump which has adequate dimensions so as
not to restrict the movement of the float switch.
Take all necessary precautions as described on page 2 before plugging in, and switching
ON.
SUITABLE HOSE, and SPARE/REPLACEMENT MULTI HOSE ADAPTERS ARE
AVAILABLE FROM YOUR CLARKE DEALER
MAINTENANCE
WARNING
Before checking the condition of the pump, ensure it is unplugged from the
mains supply. If the unit is hard wired, ensure the circuit breaker is open.
Check the pump installation regularly to ensure the base inlet is clear of leaves or other
debris.
If the pump has been used for pumping salt water, ensure it is flushed with clean mains
water thoroughly before storing.
Note that these pumps are fitted with automatic thermal overload protection. If the pump
overheats due to an obstruction in the pump, or pumping warm water for example, it will
shut off automatically. Switch the pump OFF and disconnect from the mains supply. Check
for blockages and allow the motor to cool (at least 5 minutes) before attempting to re-
start.
These pumps should require no maintenance other than regular cleaning. If the pump
starts to show signs of wear or damage, contact your CLARKE dealer for advice. Do not
use the pump if there is any damage to the mains supply cable, or to the float switch or its
cable. Do not attempt to repair the pump yourself, as you may damage the waterproof
seal and invalidate your guarantee. Repairs must be carried out by your CLARKE dealer,
or contact the CLARKE Service Department, on 020 8988 7400