20 Operator’s Manual - Vantage 17 Cable
SOLUTION FILTER CLEANING
1. Empty the solution tank (A, Fig. 20) according to the
procedure shown in the relevant paragraph.
2. Make sure that the power supply cable (H, Fig. 20) is
disconnected from the electrical mains.
3. Drive the machine on a level ground.
4. Remove the transparent cover (D, Fig. 20) and the filter
strainer (E), then clean and reinstall them on the support
(F).
MACHINE SPEED ADJUSTMENT
1. Remove the recovery tank as shown in the Use chapter.
2. Adjust the machine speed by means of the screw (A, Fig.
21), according to the following procedure:
Loosen the screw (B, Fig. 21) on the right side of the
machine, by turning it counter-clockwise.
Turn the adjusting screw (A, Fig. 21)
counter-clockwise to increase the machine speed.
Turn the adjusting screw (A, Fig. 21) clockwise to
decrease the machine speed.
After adjusting, tighten the screw (B, Fig. 21).
3. Install the recovery tank as shown in the Use chapter.
4. With the machine ready to operate, carry out hands-on
tests of the machine speed and, if other adjustments are
necessary, repeat steps 1 to 4.
NOTE:
Properly install the strainer (E, Fig. 20) in the
housing (G) of the support (F).
NOTE:
The machine speed depends on the type of floor to
be cleaned and on the choice of using brush or pad.
The machine speed can be adjusted according to
the following procedure.
Figure 20
Figure 21
G
E
A
H
F
E
D
A
B
Page view 19