Clarke SHHHAIR 50/24 Operations Instructions Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
9
TROUBLESHOOTING
PROBLEM PROBABLE CAUSE REMEDY
The compressor will not start,
or stops
and will not start
again
Bad connections Check the electrical
co
nnections
Blown fuse Replace fuse
Overload cutout switch has
tri
pped
Wai
t 25-20 mins before
attempting to restart
Compressor does not start Air receiver charged Open drain valve to
e
xp
el air. Compressor
should start again
when pressure
reduces to approx 95
psi
The compressor does not
reach the se
t pressure
and
overheats easily
Inlet Air Filter is blocked
NOTE: It is also possible that
you are
trying to use more
air than the compressor is
capable of delivering
Renew oil filler/air filter
plug
Air leaking from the pressure
swi
tch
valve when the
compressor is not running
Faulty non-return valve First drain the receiver
completely of air.
Renew the non-return
valve
Air pressure from the
regulator will no
t adjust
The diaphragm with
in the
regulator body is broken
Replace regulator
Compressor operating, but
no ai
r from outlet
Inlet air filter blocked Renew oil filler/air filter
plug
Pressure regulator closed Turn regulator
clock
wise to set
required pressure
Drain valve open Close vent valve
Bleed pipe (from Pressure
S
witc
h to non-return valve)
broken or disconnected
Reconnect or replace
bleed pipe
Page view 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 19 20

Comments to this Manuals