Maintenance cont.
Figure 34
Consult your Clarke Technology Authorized Service
Person to do the service procedures.
Use only genuine Clarke Technology parts.
How to Clean the Solution Line
If the solution line becomes clogged follow this
procedure:
1. Turn key switch "OFF" and remove the key.
2. Open brush motor cover and remove brush housing.
3. Remove brushes / pads.
4. Locate the solution valve. It is located behind the
brush motor.
5. Turn solution valve "OFF". See figure 34, A)
6. Locate the solution filter screen. It is located on the
back of the solution valve. See figure 34, B)
7. Unscrew the female garden hose connector from
the back of the solution valve. The filter screen is in
the female connector.
8. Remove the filter screen. See figure 34.
9. Clean and replace screen.
10. Attach the female garden hose connector to the
solution valve.
11. Turn solution valve to "ON".
How to Center or Offset the Brush Head
The brush head on the Encore 2426 can be centered
or offset 1 inch to the right side of the machine. To
center or offset the brush head, follow this procedure:
Recommended tools: 3/8" drive rachet, 3" extension
and 9/16" socket.
CAUTION: Before offsetting the brush head,
be sure that the recovery tank is
empty of solution. Follow the in-
structions on page 20 on how to
drain the recovery tank.
1. Turn the key switch "ON".
2. Raise the brush head by pressing and holding the
brush switch until the brush head is in its full up
position.
A