SHUTTING DOWN THE COMPRESSOR
1. To shut off the compressor, simply press DOWN on the ON/OFF knob (See
Fig. 2) . Always use this knob to shut down the compressor. NEVER USE THE
MAINS SWITCH TO STOP MOTOR.
2. Close the air outlet tap and trigger the equipment (spraygun, air tool etc)
to release air from the air hose before disconnecting the hose from the
machine.
3. Before transporting your compressor or when leaving overnight, expel all air
from the receiver by opening drain valve located at the bottom of the
receiver, and shown in fig 4.
8
MAINTENANCE
A. DAILY
1. Check the oil level before you start
and top-up if necessary - (use Clarke
SAE 40 compressor oil available from
your local dealer).
2. Drain any condensate that may
have accumulated in the receiver
by unscrewing the drain plug
beneath the air receiver (fig. 4).
Fig. 5
B. PERIODICALLY
1. After the first 5 hours of running the compressor, check the cylinder head
bolts and motor housing screws and re-tighten if any have worked loose.
2. Every 50 hours (more frequently if
used in a dusty environment), clean
the air intake filter, by carefully prising
the filter from the cover as shown in
fig. 5
Clean the sponge and the inner
housing. If necessary, the sponge
filter may be gently washed in warm
soapy water, rinsed and allowed to
dry thoroughly before refitting.
If the filter is damaged, you should
obtain a replacement immediately.
Fig. 4
Page view 6